Skip to content
BreslauLock Services
Open 24/7(226) 807-7011Open 24/7
Hands using a power driver at the end of a horizontal push bar on an open metal door. — Panic & Exit Hardware, Winterbourne
Person handling a lock cylinder at a workbench lined with cylinders, keys, small pin trays and blank key tags. — Commercial Rekeying, Winterbourne

Commercial · Winterbourne

Panic & Exit Hardware in Winterbourne

The fire inspector's note is blunt: the banquet hall's second exit still turns on a deadbolt, and the crowd it is rated to hold needs a door that opens under one motion, no key involved.

Call (226) 807-7011

In plain words

A pair of doors is its own small project, and not every pair needs the same approach. Some rim-device pairs keep their mullion and latch each leaf independently with no set closing order. Where sequencing does matter, one leaf is chosen as the inactive leaf and closes first, guided by a coordinator so the active leaf's device can seat properly into the strike or into an astragal on the inactive leaf. Removing a centre mullion calls for a compatible replacement arrangement on each leaf, which can matter for wheelchair access or for moving equipment through.

Sound familiar?

The daycare wants the yard gate and the classroom door alarmed so a staff member hears the moment it opens, without turning either into something a child could be shut behind.

How the visit goes

Panic & Exit Hardware

How the visit goes

Technician in a cap and hooded sweatshirt using a small screwdriver on the lever handle and lock case of a glass door. — Winterbourne
Hands fitting a steel door knob into the bore of a dark door, with a yellow drill and tool bag behind. — Winterbourne
  1. Confirming why the door needs this hardware

    The visit starts with the reason exit hardware is being discussed at all: an occupant load that has crossed a threshold, a fire inspector's note, a new use for the room, or an existing device that has stopped working the way it should. Confirming this first decides everything downstream, because a door required to have a releasing device is treated differently from one where an owner simply wants easier egress. Whoever is responsible for the building is asked directly what triggered the visit, and the answer is recorded alongside the door it concerns before any hardware is chosen.

  2. Testing release force and full latch engagement

    Once mounted, every device is cycled by hand repeatedly, checking that the touchpad or crossbar releases the latch under a light, even push and that the door swings clear of its frame and any threshold without binding. The strike is checked from both sides to confirm the latch seats fully when the door is pushed closed, not only when it is guided into place by hand. Any adjustment the testing reveals is made on the spot, before the device is called finished.

  3. A door that opens under one motion, every time

    What the space has afterward is straightforward: anyone inside can leave through that door with a single push on the crossbar or touchpad, no key, no second step, no need to remember which way a lock turns. Staff can be shown the motion once and it stays intuitive, because that is exactly what the hardware is built to do. Outside, entry still works the way it was set up to, through the trim chosen for that door, entirely separate from the exit function inside.

Panic & Exit Hardware

In the van

  • Request-to-exit switch

  • Force gauge

  • Astragal and mullion hardware

  • Strike and reinforcement

  • Through-fixings and mounting hardware

Technician in a cap and safety glasses holding a push bar end cap against a metal door with a red drill. — Winterbourne

Panic & Exit Hardware

What affects the quote

  1. New preparation or existing cut-outs

    A door with no prior hardware needs new holes cut and reinforced to the device's template. A door already prepared for a similar device, even an old one, is often a simpler fit with less new drilling.

  2. Access to the opening

    A ground-floor commercial door is straightforward to reach. An opening behind scaffolding, up a stairwell with no elevator, or in a space still under active construction takes longer to work at.

  3. Signage and labelling

    Any exit signage or alarm labelling the opening needs is a small addition on its own, but it is named in the quote rather than assumed to already exist on the door.

What to have ready

  • Is the existing hardware still working, or does it need replacing outright?
  • Is this for new construction, a renovation, or an existing building?
  • Is access control or an alarm system planned for any of these doors?
Call (226) 807-7011

Panic & Exit Hardware: questions

Questions
Can a padlock or extra deadbolt stay on a door that has this hardware?

No additional fastening should stay on an exit door that does not release the same way the primary device does. A hasp, padlock or separate deadbolt added at some point for extra security is a common finding on an older door, and removing or replacing it with something that releases under the same push is part of bringing that opening back to a single, reliable exit.

What counts as panic hardware?

Panic hardware is a door-latching device, usually a crossbar or touchpad running most of the door's width, that releases the latch the moment someone pushes on it from the inside. It is built and tested so a light, even push anywhere along the bar opens the door, which is why it is chosen for doors serving rooms with enough people that fumbling for a key during an exit is not acceptable.

How high should the crossbar or touchpad be mounted?

Exit-device makers publish a mounting range for their own models, and in practice a crossbar or touchpad sits no higher than about 1200 mm above the finished floor. The locksmith sets the hardware inside the maker's range and below that ceiling, allowing for anyone in the space who needs a lower reach, a wheelchair user or a shorter staff member among them.

Related services

Panic & Exit Hardware near you

Call(226) 807-7011

Request a visit

Or call (226) 807-7011 · open 24/7